ALLIANCE UU050E Specifications

Browse online or download Specifications for Electric laundry dryers ALLIANCE UU050E. ALLIANCE UU050E Specifications User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Tumble Dryer

ProgrammingTumble DryerOPL Electronic ControlRefer to Page 7 for Model IdentificationOriginal InstructionsKeep These Instructions for Future Reference

Page 2

Gas Steam/Thermal Oil Electric35 Pound CHD35G2-CA035LCHD35G2-CA035NCHD35G2-CT035LCHD35G2-CT035NCHD35G2-CU035LCHD35G2-CU035NCK035NCK035RCT035RCU035RDR3

Page 3 - Front Matter

Gas Steam/Thermal Oil Electric45 PoundStackedCKT45NCKT45RCTT45LCTT45NCTT45RDR445G2-BAT45LDR445G2-BAT45NDR445G2-BKT45NDR445G2-BKT45RDR445G2-BTT45DDR445

Page 4 - Table of Contents

Gas Steam/Thermal Oil Electric50 Pound CA050LCA050NCK050NCT050LCT050NCU050LCU050NDR50G2-BA050LDR50G2-BA050NDR50G2-BK050NDR50G2-BT050DDR50G2-BT050LDR50

Page 5

Gas Steam/Thermal Oil Electric55 Pound CA055LCA055NCK055NCK055RCT055LCT055NCT055RCU055LCU055NCU055RDR55SG2-BA055LDR55SG2-BA055NDR55SG2-BK055NDR55SG2-B

Page 6

Gas Steam/Thermal Oil Electric75 Pound CA075LCA075NCK075NCK075RCT075LCT075NCT075RCU075LCU075NCU075RDR75G2-BA075LDR75G2-BA075NDR75G2-BK075NDR75G2-BK075

Page 7

Gas Steam/Thermal Oil Electric120 Pound CA120LCA120NCK120NCT120LCT120NCU120LCU120NDR120G2-BA120LDR120G2-BA120NDR120G2-BK120NDR120G2-BT120LDR120G2-BT12

Page 8

Gas Steam/Thermal Oil Electric200 Pound CA200LCA200NCT200LCT200NCU200LCU200NDR200G2-BA200LDR200G2-BA200NDR200G2-BT200LDR200G2-BT200NDR200G2-BU200LDR20

Page 9

Preliminary Information About the ControlThis control is an advanced, programmable computer that lets theowner control most machine features by pressi

Page 10 - Introduction

End of Cycle External Signal = Enabled (5 seconds)Clean Lint Screen Reminder = OffDisplay Limit Errors = DisabledManual Diagnostics = Enabled*Manual P

Page 11 - Part No. 70444901ENR8

Control Identification Operational KeypadThe control includes five keypads. These functions are availableto the operator and are intended to control a

Page 13

Keypad DescriptionSTART Press to start the selected cycle, select an option when in the menu or save a valuewhen editing a parameter.Status Indicator

Page 14

Time DryCycleDisplay6 DigitDisplay DescriptionDisplay 5 SAVE Custom Save Mode Dis-playTable 2MoistureDry CycleDisplay6 DigitDisplay DescriptionDisplay

Page 15

has been reached or the programmed cool down time expires,which ever happens first. End of Cycle ModeThe control enters End of Cycle Mode after the co

Page 16 - Nameplate Location

Machine Cycle Definition and OperationThere are 30 machine cycles that can be selected and run. Ma-chine cycles can be modified or made “unavailable”

Page 17 - Preliminary Information

Entering the Manual ModeFor programming, testing, and retrieving information from thecontrol, it is often necessary to enter the Manual Mode by follow

Page 18 - Entering Program Mode

Manual Mode: Enter by pressingStop ( ), then Back (ß), then Up (á) keypads“ Prog”Manual Programming“Audit ”Manual Read Audit“rESEt”Manual Reset“diA

Page 19 - Control Identification

Programming Control What Can Be Programmed?This feature allows the owner to program cycle parameters andother features by using the keypads. The contr

Page 20 - Operation Modes

OptionNumberOptionDisplay DescriptionDefaultValue Value Range7 CHHS3- Segment 3 - CHHS31 (Segment 3 Enable/Disable), CHHS32 (Seg-ment 3 Time), CHHS33

Page 21

OptionNumberOptionDisplay DescriptionDefaultValue Value Rangec tEnP 3 Global Medium Tempera-ture160°F[71°C]140°-160°F [60°-71°C](50, 75, 120, 170, 200

Page 22

OptionNumberOptionDisplay DescriptionDefaultValue Value Rangef rtC 6 Year - 0-99g rtC 7 Daylight Savings 1 1 (Enable), 0 (Disable)14 rAPdEn Manual Rap

Page 23 - Machine Cycle Operation

Front MatterWARNINGMachine installations must comply with minimumspecifications and requirements stated in the appli-cable Installation Manual, any a

Page 24 - Entering the Manual Mode

“CyCLE-”Cycle Programming“CHHEn”Cycle HH Enable Disable“CyCHH”Cycle to be programmed“CHHtyP”Cycle HH TypePress the “CHHnt”Cycle HH Material Type“CHHtP

Page 25 - Figure 6

“CHHS1-”Segment 1“CHHS2-”Segment 2 “CHHS11”Segment 1Enable/Disable“CHHS12”Segment 1 Time“CHHS13”Segment 1 Temperature“CHHS14”Segment 1 Auto DryTarget

Page 26 - Programming Control

“CHHS4-”Segment 4“CHHS5-”Segment 5 “CHHS41”Segment 4Enable/Disable“CHHS42”Segment 4Time“CHHS43”Segment 4 Temperature“CHHS44”Segment 4 Auto DryTarget L

Page 27

“CHHCd-”Cool Down“CHHr-”Reversing“CHHCd1”Cool DownTemperature“CHHCd2”Cool Down Time“CHHCd3”Cool Down Segment Reversing Enable/Disable“CHH r1”Cycle Rev

Page 28

“rEu-”Global ReversingParameters“tEnP-”Global Temperatures “rEu 1”Rotate Time“rEu 2”Stop Time“rEu 3”Advanced Reversing(On/off)“ tEnP 1”Global VeryLow

Page 29

“Aud 1 ”End of Cycle(On/off)“ Aud 2 ”End of CycleDuration“Aud 3 ”Keypad Feedback(On/off)“ESig 1”External SignalEnd of Cycle (on/off)“ESig 2”External S

Page 30 - Figure 7

“rtC 1”Minutes“rtC 2”Hours“rtC 3”Day“rtC 4”Date“rtC 5 ”Month“rtC 6”Year“rtC 7”Daylight Savings(on/off)“AIg”Auto Ignite Retry“diAgEn”Manual Diagnostics

Page 31 - Figure 8

Collecting Audit InformationThis feature allows the owner to retrieve audit information storedin the tumble dryer by pressing a sequence of pads on th

Page 32 - Figure 9

Manual ResetThis feature allows the owner to reset the tumble dryer control’sprogramming data to the factory default settings by pressing a se-quence

Page 33 - Figure 10

Custom SaveThis feature allows the owner to save a current cycle. For timedry cycles, the custom save will reprogram the cycle time to thetime that ha

Page 34 - Figure 11

Table of ContentsFront Matter... 3Introduction...

Page 35 - Figure 12

Testing Machine and Electronic Control Func-tionsThis feature allows the owner to run diagnostic tests on varioustumble dryer operations without servi

Page 36 - Figure 13

Diagnostic (Testing) Mode – Quick Reference ChartdAFS Airflow Switch TestdFAn Fan Motor TestddAnPr Damper Motor Test*drEuSE Reverse Motor Test*drotAt

Page 37 - Collecting Audit Information

TMB1374R_SVG“dSoft”Control Software Version Number TestPress the Up (á) or the Down (â) keypad to scroll through the Diagnostic Test options.“diAg””Di

Page 38 - Manual Reset

Diagnostic Test Descriptions Control Software Version Number TestThis option displays the control software version number. Tostart test, control must

Page 39 - Custom Save

DS8 DS7 DS6 DS5 DS4 DS3 DS2 DS1 DisplayOFF OFF OFF OFF ON OFF OFF OFF dSC008OFF OFF OFF ON OFF OFF OFF OFF dSC016OFF OFF ON OFF OFF OFF OFF OFF dSC032

Page 40 - How to Exit Testing Feature

To enter, press the Startkeypad. The display will show C HHH,with HHH the number corresponding to the machine capacity.Refer to Table 8 .Value Descrip

Page 41

NOTE: This test does not count towards the total ma-chine run time operation.To exit Damper Motor Test, press the Back keypad. The controlwill return

Page 42 - Figure 14

Production Test Cycle Quick Reference TableDisplay Test Mode CommentsS HH Software Version HH is the software version number.Ct HHH Control Type 2, 3,

Page 43 - Diagnostic Test Descriptions

Machine Errors PDA Communications ErrorThese errors may occur during communications. When an erroroccurs, the display indicates the error message on t

Page 44

closed for at least 5 seconds (it is flagged as an airflow switchbounce). If there are 5 airflow switch bounces within 5 minutesthe control will go to

Page 45

Entering the Manual Mode... 24How to Enter the Manual Mode...

Page 46 - Production Test Cycle

Error CodesFollowing is a list of possible error codes for an electronic con-trol. Errors beginning with EI refer to external device Infra-redcommunic

Page 47

Dis-play Description Cause/Corrective ActionE rot Rotation Sensor Error Check for broken or worn belts. Make sure machine is not over loaded and check

Page 48 - Machine Errors

Communication ModeThis mode is entered whenever the control is communicatingwith a PDA. Refer to PC and PDA Application User Instruc-tions. Infra-red

Page 49

Cycle ChartsCycle No. Cycle Name Cycle Type Material Type Reversing Temperature TargetMoistureor Time1 Towels Moisture Dry Cotton OFF 190°F [88°C] 1%2

Page 50 - Error Codes

27 5 Minute High Time Dry n/a OFF 190°F [88°C] 5 minutes28 5 Minute Med Time Dry n/a OFF 160°F [71°C] 5 minutes29 5 Minute Low Time Dry n/a OFF 140°F

Page 51

PDA Communications Error... 48Open Thermistor Error...

Page 52 - Communication Mode

Introduction Model IdentificationInformation in this manual is applicable to these tumble dryermodels:Gas Steam/Thermal Oil Electric25 Pound CHD25G2-C

Page 53 - Cycle Charts

Gas Steam/Thermal Oil Electric30 Pound CHD30G2-CA030LCHD30G2-CA030NCHD30G2-CT030LCHD30G2-CT030NCHD30G2-CU030LCHD30G2-CU030NCK030NCK030RCT030RCU030RDR3

Page 54

Gas Steam/Thermal Oil Electric30 PoundStackedCHD30STG2-CAT30LCHD30STG2-CAT30NCHD30STG2-CTT30LCHD30STG2-CTT30NCHD30STG2-CUT30LCHD30STG2-CUT30NCKT30NCKT

Comments to this Manuals

No comments