Mooring Arrangement 8 Point mooring with central control and CCTV
arrangement. All winches on Main Deck
Fair Leads 8 Nos x 38 mm.
Deck Sheaves 8 Nos x 38 mm.
Marker Buoy 8 Nos, with lifting pad 02 Nos for each buoy, length 72" ,
diameter 56" , bore diameter 50mm
Anchor Wire 4 Nos x 38 mm X 1000 Mtrs - IWRC EIPS RL
Galvanized (Brand Usha Martin) with 1 end closed
spelter socket coiled in inner drum.
4 Nos x 38 mm Dia X App. 1000 Mtrs - ( Optional ,
Currently onboard on drum) IWRC EIPS RL
Galvanized (Brand Usha Martin) with 1 end closed
spelter socket coiled in inner drum )
Anchor 03 Nos x Stockless - 9.08 Tons
05 nos x Stockless -7 Ton each.
Main Generator 01 Nos 625 KVA, 500 KW , 3 Phase , 60Hz, Volt-480 ,
Amp- 753, Alternator , make- BEMAC , type brush less,
synchronous generator , Sr.no-172954111, made in USA
and connected with GM engine 16V-71, Sr.no-16VA
6018* 7163-7305*
01 Nos 625 KVA, 500 KW , 3 Phase , 60Hz, Volt-480 ,
Amp- 753, Alternator , make- DELCO AC , type brush
less, synchronous generator , Sr.no-151E70, Model no-
E597341 and connected with GM engine 16V-71, Sr.no-
16VA * 7422*
CRANE Generator 02 Nos 313 KVA, 250 KW , 3 Phase , 60Hz, Volt-480 ,
Amp- 376, Alternator , make- DELCO , Model no-
2E7079M2 & E5229R8, Type brush less, Generator ,
Sr.no-151-E-70 & 26-L-75 and connected with GM
engine 12V-71, Sr.no-12VA11219 * 7122-7001* &
12VA60681 * 7123-7300*
Lighting generator 1 No x 82 KVA Kirloskar Engine & Stamford Alternator
380 415 lt/65 6 k /3Ph /50 60HZ *
CAPTIVE POWER :-
380-415 volt/65.6 kw/3Phase/50-60HZ *
1 No x 160 KVA Cummins & Stamford Alternator*380-
415 volt/148 kw/3Phase/50-60HZ *
A) 480 V , 3 phase 60 Hz main synchronization panel
with shore power panel along with Motor control centre
,SIS type 14/41 stranede with A600 volt 90degree
thermosetting insulation of the Heat resistance, moisture-
resistant & flam retarding Grade,
b) A) 480 V , 3 phase 60 Hz main switch board panel
with Bus-coupler system panel along with Slip-ring
provision through ATS to connect with Main switch
board.
c) Main switch board for 220 3phase 50 hz for all
lighting and socket arrangement
d) Power distribution board 415 volt /3phase/50hz for
different equipment.
e) Power distribution board 220 volt /3phase/50hz for
different equipment.
Step down transformer 01 no 480/208 volt/3phase/60Hz/45 kva Dry type air
cooled in Engine room
01 no 240-480/ 120-240 volt /60Hz/2.5 KVA /singal phase
insulated transformer in crane
01 no 240-480/ 120-240 volt /60Hz/15 KVA /singal phase
insulated transformer in crane
03 nos 240-480/ 120-240 volt /60Hz/25 KVA /single phase
insulated transformer in electrical control room
01 no 440/240 volt/3phase/60Hz/30 kva Dry type air
cooled In Electrical control room,
01 no 480/208-120 volt/3phase/60Hz/ 112.5kva Dry type
air cooled In Electrical control room,
MACHINERY :-
Main Switch Board
Page view 2