Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
11. HEATER ASSEMBLY OR BURNER DOES NOT SHUT OFF
12. CLOTHES DO NOT DRY
POSSIBLE CAUSE TO CORRECT
Improper motor switch. Timer must be in a heat
setting.
Test switch and replace if inoperative.
Motor does not stop. Refer to Paragraph 4.
Incorrect wiring. Refer to appropriate wiring diagram.
Heater assembly shorted. Remove heater assembly and check for short.
POSSIBLE CAUSE TO CORRECT
Heater assembly does not heat or burner does not
ignite.
Refer to Paragraph 5.
Too much water in articles being dried. Remove excess water.
Clothes load too large. Remove part of load. A normal washer load is a normal
dryer load. Maximum load: Dryer cylinder one half full of
wet clothes.
Excessive lint on lint filter. Clean lint filter.
Load too small. Add one or two bath towels to load.
Automatic cycle. Adjust to more dry setting.
Three position heat selector switch or timer set on
FLUFF or inoperative.
Reset switch or timer, or test and replace the switch or
timer if inoperative.
Improper or inadequate exhaust system. Refer to Installation Instructions (supplied with dryer)
for exhaust requirements.
Heater assembly or burner shuts off prematurely. Refer to Paragraph 9.
Gas Models: Gas line pressure too high or too low. If natural gas line pressure to dryer exceeds 8 inch water
column pressure, or is lower than 4 inch water column, ask
gas company to correct.