ALLIANCE AE7133 Service Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 125
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
60549 45
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
IMPORTANT: The seal can be adhered to the
bulkhead using 3M-1300 Sealant (obtain locally).
This is accomplished by applying a bead of 3M-1300
Sealant around the entire flanged area where the
felt seal contacts the bulkhead. Strap must be
installed with cupped surface down against the seal
to hold the felt seal more firmly in place on the
bulkhead. Seal must be held securely under strap
and folded under flanged edge around entire
bulkhead.
52. CYLINDER BELT
a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
c. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Disengage belt from motor and idler pulleys,
Figure 24.
e. If present, disconnect cylinder light wires.
f. Remove four screws holding bulkhead to front
flange of cabinet. Lift complete bulkhead
assembly out of slots in cabinet. Refer to
Figure 30.
IMPORTANT: During reinstallation of front
bulkhead, be sure that air duct is properly
positioned with the flange inside of the felt seal on
the exhaust fan cover.
g. While supporting cylinder, carefully remove
belt off cylinder.
NOTE: When installing belt, be sure belt is
properly installed on motor and idler pulleys, and is
on the correct side of the idler lever. Refer to
Figure 24. Belt must be positioned around cylinder
between center and rear baffle screws with the
ribbed surface against the cylinder. After installing
belt, rotate cylinder manually to check that belt is
properly aligned.
53. CYLINDER ASSEMBLY
a. Remove two screws from the bottom edge of
the front panel. Refer to Figure 12.
b. Swing the bottom of the panel away from the
dryer to disengage hold-down clips and guide
lugs from cabinet top. Refer to Figure 12.
c. Disconnect wires from door switch. Refer to
Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
d. Disengage belt from motor and idler pulleys.
Refer to Figure 24.
Figure 31
DRY861S
CYLINDER GLIDE
ATTACHING SCREWS
SPRING
SEAL MUST BE
POSITIONED UNDER
FLANGED EDGE
FELT
SEAL
SEAL
STRAP
(Installed
with
cupped
surface
against
seal)
BULKHEAD
Page view 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 124 125

Comments to this Manuals

No comments