Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
e. Turn burner orifice spud out of gas valve and
install No. 58719 Natural Gas Burner Orifice
Spud (metal stamped #44). Torque new burner
orifice spud to 30 inch-pounds (3.4 N-m).
f. Reinstall burner tube, tighten hex head screw
firmly and reconnect igniter leads.
g. Remove the block open plug and install No.
58768 Vent Screw. Refer to Figure 47.
h. Install No. 60516 Valve Converted to Natural
Gas
Sticker to top side of gas valve so it covers
the gas valve part number.
Refer to Figure 47
.
i. Sign and date each of the two No. 60521
Natural Gas Stickers. Install one of the No.
60521 Natural Gas Stickers over the top three
lines of the old sticker on rear of cabinet. Refer
to Figure 48. Then place the second sticker over
the top three lines of the old sticker located on
backside of access door. Refer to Figure 46.
j. Apply the No. 60514 Conversion Plate to the
inside of the loading door opening above the
nameplate. Refer to Figure 49.
k. Turn the gas line shut-off valve handle to the
open position and connect electrical service.
Refer to Figure 47.
l. Check gas valve pressure as follows:
(1) Remove pressure tap pipe plug. Refer to
Figure 47.
(2) Connect a U
tube manometer (or similar
pressure gauge) to the pressure tap.
Refer
to Figure 50
.
(3) Start dryer, pressure should be 3.5 ± .2
inches (8.89 ± .508 cm). Refer to
Figure 50.
Figure 48
DRY964S
APPLY NO. 60518 or 60519
GAS STICKER HERE
(Depending on type of gas)
Figure 49
APPLY NO. 60515
CONVERSION
PLATE
HERE