Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
To Test Timer Contact Points
1. Remove six screws (three on top and three at
lower front) holding the hood assembly to the
control hood rear panel and cabinet top. Refer to
Figure 8 or 9.
2. Disconnect wires from timer.
NOTE: Refer to appropriate wiring diagram when
rewiring timer.
3. Set test meter to read OHMS and put meter
probes to terminals indicated in table below.
4. Starting with timer knob indicator in OFF
position at top of timer, slowly turn timer knob
clockwise until indicator is again pointing toward
OFF position at top of timer. Meter should
register zero reading when circuit being tested
is completed by timer. Refer to appropriate
wiring diagram for Timer Cycle Chart showing
when circuit is made.
Circuit to be Tested
Timer No.
59418
Timer No.
59420
Timer No.
59421
Timer No.
59422
Timer No.
59497
Timer No.
61402
Timer Motor L1 and M L1 and M L2 and T L2 and T L2 and T L2 and T
Signal Control P and B B and P P and B B and B P and B
Motor L1 and M L1 and M L1 and M L1 and M L1 and M L1 and M
Heat L1 and H L2 and H L2 and H L2 and H
High Temperature Heat ———L2 and H2 L2 and H2
Low Temperature Heat
(Delicate)
———L2 and H1
L2 and H1
and H2
Push-to-Start M and S M and S ———