ALLIANCE AE7133 Service Manual Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 125
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
54 60549
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the dryer(s) before servicing.
Close gas shut-off valve to gas dryer(s) before servicing.
Never start the dryer(s) with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
(1) Remove two screws holding heater
assembly to heater box, then pull heater
assembly down and away from heater box.
Refer to Figure 19.
(2) Disconnect wire harness from limit
thermostat nd thermal fuse. Refer to
Figure 19.
f. Remove screw holding heat shield to dryer
base. Refer to Figure 34.
g. Remove lint filter. Refer to Figure 10.
IMPORTANT: When installing the filter, be sure to
place the filter into the front air duct with the word
FRONT facing the front of the dryer.
h. Remove screws holding air duct to front
bulkhead and remove air duct. Refer to
Figure 21.
NOTE: When reassembling, be sure felt seal on
exhaust fan cover makes air tight seal on flange of
air duct. Refer to Figure 20.
i. Disconnect wires from thermistor and/or
thermostat or thermostat and heater. Refer to
Figure 20.
NOTE: Refer to appropriate wiring diagram when
rewiring thermistor and/or thermostat or
thermostat and heater.
j. Remove cylinder belt from idler and motor
pulleys. Refer to Figure 24.
k. Remove two screws holding motor mounting
bracket to dryer base. Refer to Figure 23. Then
pull complete assembly out through front of
dryer.
l. Disconnect wires from motor switch and
remove harness clip from motor bracket. Then,
set motor and exhaust assembly off to the side.
Refer to Figure 26.
m. Remove screw holding bracket on exhaust duct
to rear of cabinet and pull duct out through rear
of cabinet. Refer to Figure 22.
IMPORTANT: When reinstalling motor and
exhaust assembly, be sure wire harness on right side
is clipped to motor mounting bracket and is routed
along dryer base (between motor mounting bracket
and right side of cabinet). Refer to Figure 23. Tab on
rear of motor mounting bracket must be slid into
slot in dryer base.
n. Remove two screws from front edge at each
side of cabinet. Refer to Figure 30. Then
remove remaining screws from around bottom
of cabinet and lift cabinet off base.
o. Remove leveling legs and locknuts from base
and reinstall on new base.
Page view 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 124 125

Comments to this Manuals

No comments