ALLIANCE JT37CGI Service Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
M411429 11
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Section 3
Troubleshooting
IMPORTANT: Refer to appropriate wiring diagram for aid in testing tumbler components.
1. MOTOR DOES NOT START
POSSIBLE CAUSE TO CORRECT
Electrical power off or fuses blown. Check power and fuses, replace fuses if necessary
Loading door not closed or inoperative door switch. Close door, or test switch and replace if inoperative.
Door switch improperly adjusted. Refer to Adjustment Section in this manual for door
switch adjustment.
Trunnion shaft assembly binding in
trunnion housing bearings.
Replace trunnion housing bearings.
Start circuit not completed. Press start switch, or test switch and replace if
inoperative.
Idler shaft binding in idler housing bearings. Replace bearings.
Inoperative motor. Have motor tested and replace if inoperative.
Non-Metered Models: Timer improperly set. Turn drying timer clockwise to desired setting.
Non-Metered Models: Inoperative timer or relay. Test timer and relay and replace if inoperative.
Metered Models: Improper coins inserted in
accumulator.
Check that proper coins are inserted.
Metered Models: Accumulator knob improperly
set after coins were inserted.
Turn knob clockwise to its full limit of travel.
Metered Models: Inoperative run switch
(accumulator).
Test run switch and replace if inoperative.
Broken, loose, or incorrect wiring. Refer to wiring diagram located on back of tumbler or in
literature packet.
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 100 101