M411429 97
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
117. LOADING DOOR SWITCH
Refer to Figure 43.
The door switch should be adjusted so the cylinder
stops when door is opened two inches (51 mm),
plus or minus 1/4 inch (6 mm). This switch is a
normally open switch and is closed when the door
is closed.
a. Close door and start tumbler, then slowly open
loading door. Cylinder and heat system should
shut off when door is open two inches (51 mm)
plus or minus 1/4 inch (6 mm).
b. Slowly close loading door. When door is two
inches (51 mm) from being fully closed, the tab
on the door should contact the switch rod and
depress it enough to close the switch with an
audible click.
c. If tab does not depress the switch rod enough to
operate the switch, bend tab outward and repeat
steps a and b.
118. CYLINDER DOOR STRIKE
Refer to Figure 44.
The door strike must be adjusted so it has
sufficient tension to hold loading door closed
against the force of a tumbling load. The door
strike is properly adjusted when 8-15 lbs. (17.6-33
kg) of pull is required to open door.
To adjust, open door, loosen acorn nut and turn
door strike screw in or out as required. Retighten
acorn nut.
Figure 43
SWITCH
ARM
ADJUSTING
SCREWS
DOOR
SAFETY
SWITCH
INTERLOCK
ROD
SWITCH
BRACKET
TAB
T249IE1A
Figure 44
T048IE1A
DOOR
STRIKE
DOOR
LATCH
ACORN
NUT