70 M411429
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
86. STOVE HIGH LIMIT THERMOSTAT
(Gas Models)
NOTE: Steps a through d, and f apply only
to energy saver models. The stove high limit
thermostat is more readily accessible on non-energy
saver models.
a. Remove control panel.
b. Remove screw holding cover plate to wire-way
(older models); or, remove screw holding cover
to junction box or airflow switch box (older
models). Remove cover. Refer to Figure 17.
c. Disconnect stove high limit thermostat wires in
wire-way or in junction box.
d. Remove conduit nut from BX cable on inside of
wire-way or junction box. Refer to Figure 17.
e. Remove two screws holding thermostat and
bracket to rear side of burner. Refer to
Figure 17.
NOTE: This will allow the conduit to follow through
between burner and cabinet when thermostat and
bracket assembly are slid toward front of tumbler
(energy saver models only).
f. Carefully slide assembly, with conduit, toward
front of tumbler far enough to permit removal
of complete assembly from burner.
g. Remove two screws holding cover to mounting
bracket. Refer to Figure 18
h. Disconnect wires from thermostat.
i. Remove two screws holding thermostat to
mounting bracket. Refer to Figure 18.
Figure 17
AIRFLOW
SWITCH
CONDUIT
NUT
SCREWS
STOVE
HIGH LIMIT
THERMOSTAT
CABINET
HIGH LIMIT
THERMOSTAT
OLDER MODELS
T024SE1A
JUNCTION
BOX
CONDUIT
NUT
SCREWS
STOVE
HIGH LIMIT
THERMOSTAT
NEWER MODELS
T025SE1A