Page view 80
M411429 83
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
108. TRUNNION HOUSING ASSEMBLY
a. Remove cylinder assembly.
b. Remove upper guide rail bolt and nut. Refer to
Figure 32.
c. Remove four cap screws holding trunnion
housing assembly to rear of cabinet. Refer to
Figure 31.
d. Remove four bearing retainer screws holding
the small bearing in housing. Refer to
Figure 33.
e. Use a hammer and hardwood dowel to remove
bearings.
IMPORTANT: When installing new bearings, apply
a film of oil to the bearing cavity surfaces in the
housing and to the outside diameter of the bearings.
IMPORTANT: If a press is not available to install
bearings, tap bearings into housing.
f. Reinstall chain guard on tumbler. Refer to
Figure 27.
Figure 32
TU039-SV
BOLT
IDLER
HOUSING
(Includes
M400039
SNAP RING
BEARING
CARRIAGE
BOLT
BEARING
NUT
LOCKWASHER
SLEEVE
WASHER
NUT
LOCKWASHER
KEY
IDLER
SPROCKET
DRIVE
SPROCKET
DRIVE
CHAIN
IDLER
SHAFT
IDLER
HOUSING
CONNECTING LINK
(Included with
M401425 CHAIN)
Figure 33
LARGE
BEARING
TRUNNION
HOUSING
SMALL
BEARING
BEARING
RETAINER
SCREW
WASHER
TU192-PT