ALLIANCE JT37CGI Service Manual Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
M411429 57
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
61. COIN METER
Refer to Figure 5.
a. Remove control panel.
b. Disconnect wires from heat and run switches.
c. Cut remaining motor wire and joining white
wire at wire nut.
d. Remove four speed nuts holding coin meter to
coin meter frame.
NOTE: Refer to wiring diagram when rewiring coin
meter. Connect wires cut in step c above with
new wire nut.
Figure 4
SCREW
TIMER
MOTOR
TIMER
ASSEMBLY
TU001-SV
Figure 5
HEAT
SWITCH
RUN
SWITCH
COIN
METER
SPEED
NUT
TIMER
MOTOR
TU060-SV
Page view 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 100 101