Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
113. REVERSING CONTROL ELECTRICAL
COMPONENTS
Refer to Figure 39.
NOTE: All electrical components except the
reversing/nonreversing switch are located in the
reversing control box on the rear of the tumbler.
The reversing/nonreversing switch is mounted on
the upper right hand corner of the control panel.
a. Reversing/Nonreversing switch:
(1) Remove control panel.
(2) Disconnect wires from switch terminals.
NOTE: Refer to wiring diagram when rewiring
switch.
(3) Manual Timer Models: Remove knurled
nut holding switch to front of control panel.
MM Models: Compress tabs on switch
from rear side of control panel. Slide
switch forward out of control panel.
(4) Remove and save hex nut from switch
shaft. Knurled nut is furnished with the
switch.
b. Reversing timer assembly:
(1) Remove two attaching screws and cover
from control box.
(2) Disconnect wires from timer motor and
switches, or from solid state reversing
timer.
NOTE: Refer to wiring diagram when rewiring
timer motor and switches.
(3) Remove two screws holding timer to back
wall of control box.
(4) Models not having solid state reverser:
Remove timer motor and/or switches as
necessary for replacement. If timer itself is
faulty, replace the complete assembly,
including timer motor and switches.
c. Reversing contactor:
(1) Remove two attaching screws and cover
from control box.
(2) Disconnect wires from contactor coil
terminals.
NOTE: Refer to wiring diagram when rewiring
reversing contactor.
(3) Remove screws holding contactor to back
wall of control box.
(4) To remove coils for replacement, remove
single screw holding each coil to contactor
frame.
(5) If contactor problem is something other
than a defective coil, replace complete
contactor assembly.
d. Fan motor contactor:
(1) Remove two attaching screws and cover
from reversing control box (earlier
versions); or remove junction box cover
(later versions).
(2) Disconnect wires from contactor terminals.
NOTE: Refer to wiring diagram when rewiring fan
motor contactor.
(3) Remove two screws holding fan motor
contactor to back wall of reversing control
box, or junction box.
e. Transformers (480 volt electrical system
only):
(1) Remove two attaching screws and cover
from reversing control box.
(2) Disconnect leads from transformer
terminals.
NOTE: Refer to wiring diagram when rewiring
transformer.
(3) Remove four screws holding transformer
to back wall of reversing control box.