ALLIANCE JT37CGI Service Manual Page 71

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 70
M411429 73
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
89. STEAM COILS
a. Shut off inlet and outlet valves and disconnect
flex hoses from steam coils
b. Remove screws holding cover to top of steam
heating unit and remove cover.
c. Remove screws holding steam coils to coil
frame.
d. Remove steam coils by lifting straight up and
out of tumbler.
IMPORTANT: When removing or replacing steam
coils, be careful not to damage fins on steam coils.
90. LOADING DOOR ASSEMBLY
Refer to Figure 21 and Figure 22.
a. Open loading door.
b. While supporting door, remove upper hinge
bolt holding door to hinge bracket.
c. Remove door from hinge bracket.
NOTE: Nylon washer must be in place on lower pin
when reinstalling loading door.
Allow steam coils and valve to cool down
before attempting any service procedures.
W249
WARNING
Figure 21
SCREW
LOADING
DOOR
DOOR
HANDLE
TU030-SV TU031-SV
LOADING
DOOR
BAR
ATTACHING
SCREW
BAR
ATTACHING
SCREW
DOOR
BAR
ALTERNATE STYLEREGULAR STYLE