22 M411429
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
22. TUMBLER WILL NOT START, TIME ON DRYING TIMER, DOOR CLOSED
REPLACE
RELAY
CHECK FOR
BROKEN WIRE
FROM CONTROL
RELAY TERMINAL 1
REPLACE
PUSH-TO-START
SWITCH
CHECK FOR
BROKEN WIRE
OR POOR
CONNECTION
AT HARNESS PLUG
CHECK FOR
LINE VOLTAGE
INTO DOOR SWITCH
CHECK FOR
LINE VOLTAGE
OUT OF
DOOR SWITCH
CHECK FOR
LINE VOLTAGE AT
TERMINAL 3 OF
CONTROL RELAY
CHECK FOR
LINE VOLTAGE
TO MOTOR
CHECK FOR
LINE VOLTAGE ACROSS
COIL TERMINALS
OF CONTROL RELAY
HAS SWITCH ROD
MECHANICALLY
ACTUATED
DOOR SWITCH?
CHECK FOR
LINE VOLTAGE ON
TERMINAL B
OF DRYING TIMER
CHECK FOR
LINE VOLTAGE ON
TERMINAL 1 OF
CONTROL RELAY
CHECK FOR
LINE VOLTAGE INTO
PUSH-TO-START
SWITCH
PRESS
PUSH-TO-START
SWITCH. CHECK FOR
LINE VOLTAGE OUT
OF PUSH-TO-START
SWITCH
ADJUST
DOOR SWITCH
ROD
REPLACE
DOOR
SWITCH
CHECK FOR
BROKEN
WIRE
OR POOR
CONNECTION
AT
HARNESS
PLUG
CHECK
ELECTRICAL SERVICE
TO TUMBLER
(Fuses/Circuit Breaker)
REPLACE
MOTOR
REPLACE
TIMER
YES
NO
YESYES
NO NO
YES
NO
NO
NO
YES YES YES
YES
NO NO
NO
NO
YES
MANUAL TIMER MODELS
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 100 101