60 M411429
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
65. TRANSFORMER
(Automatic Pilot Ignition Models)
Refer to Figure 11.
a. Remove control panel.
b. Disconnect transformer wires at electronic
package.
c. Disconnect remaining wires from transformer
at connectors.
NOTE: Refer to wiring diagram when rewiring
transformer.
d. Remove nut holding transformer to cabinet.
Figure 10
WARNING
T014SE3A
SENSING
PROBE
LOCKING
TABS
THERMOSTAT
SENSING PROBE
THERMOSTAT
SENSING TUBE
LINT
SCREEN