ALLIANCE JT37CGI Service Manual Page 69

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 68
M411429 71
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
87. CABINET HIGH LIMIT THERMOSTAT
(Energy Saver Gas Models)
a. Disconnect electrical service to tumbler.
b. Remove chain guard.
c. Disconnect wires from thermostat.
d. Remove two screws holding thermostat to
vertical duct.
(Non-Energy Saver Gas Models)
Refer to Figure 19.
a. Disconnect electrical service to tumbler.
b. Remove lint compartment door.
c. Remove two screws holding thermostat
mounting bracket to cylinder shroud.
d. Remove two screws holding cover to mounting
bracket.
e. Disconnect two wires from thermostat.
f. Remove two screws holding thermostat to
mounting bracket.
g. To remove thermostat wire assembly.
(1) Repeat steps d through l, above.
(2) Pull wires through bushing in thermostat
mounting bracket and then push wire out
through hole in back of lint compartment.
(3) Remove wire cover and junction box cover
from rear of tumbler.
(4) Disconnect wires from inside of junction
box, and pull wires from junction box and
wire way.
NOTE: Refer to wiring diagram when reconnecting
thermostat wires.
Figure 18
TU026-SV
STOVE
HIGH LIMIT
THERMOSTAT
MOUNTING
BRACKET
COVER
SCREWS
SCREWS
Page view 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 100 101

Comments to this Manuals

No comments