ALLIANCE JT37CGI Service Manual Page 76

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 75
78 M411429
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
97. WIRE COVER or WIRE CHANNEL
COVER PLATE
Refer to Figure 27.
a. Remove single screw holding wire channel
cover plate to wire channel (older models); or
remove six screws holding wire cover to rear of
tumbler (new models).
b. Remove wire cover or wire channel cover plate.
IMPORTANT: When reinstalling cover, make sure
the wires and thermostat sensing tube (if equipped)
are not pinched between rear of cabinet and wire
cover or between cover plate and channel.
98. DRIVE GUARD
a. Support drive guard and remove screws
holding guard to rear of tumbler. Refer to
Figure 27.
b. Reinstall drive guard.
99. DRIVE BELT
Nonreversing Tumblers
a. Remove drive guard. Remove four clips (older
models) or two screws (newer models) holding
belt guard assembly to motor bracket. Refer to
Figure 29. Remove belt guard.
b. Remove chain.
c. Loosen nut on idler housing attaching bolt.
Refer to Figure 30. Drop idler housing to
bottom of slots.
d. Remove lower bolt and nut from guide rail.
Refer to Figure 30. Hinge guide rail out and slip
belt out from under guide rails.
e. Slip new belt under guide rail and onto sheave
and motor pulley. Refer to Figure 31.
NOTE: After reinstalling belt and chain, adjust
belt, then adjust chain.
Reversing Tumblers
a. Support drive guard and remove the screws
holding it to the back panel of the tumbler.
Leave the belt guard attached to the top of the
drive guard.
b. Loosen four capscrews holding motor
mounting bracket to side brackets. Lower
motor and mounting bracket until holding
capscrews bottom in the mounting slots.
c. Slip drive belt off of the motor pulley.
d. Disconnect the wires from motor.
e. Slip drive belt off of sheave, and remove drive
belt by working it over the top of the guide rails.
f. Slip the new belt onto the sheave and the motor
pulley. Adjust belt tension.
Figure 28
T037SE1A
NEWER MODELS
AIRFLOW
SWITCH
MOUNTING
SCREWS
SWITCH
LEVER
SWITCH
BOX
MOUNTING
BRACKET
Page view 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 100 101

Comments to this Manuals