88 M411429
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
112. CYLINDER DRIVE MOTOR
(Reversing Tumblers)
Refer to Figure 38.
a. Support chain guard and remove the screws
holding it to the back panel of the tumbler.
Leave the belt guard attached to the top of the
chain guard.
b. Older Models: Loosen four capscrews holding
motor mounting bracket to side brackets.
Lower motor and mounting bracket until
holding capscrews bottom in the mounting
slots. Refer to Figure 38.
Newer Models: Loosen locking bolt and back
adjusting screw out to loosen belt. Refer to
Figure 46.
c. Slip drive belt off of the motor pulley.
d. Disconnect the wire harness from motor.
e. Remove the four capscrews, nuts, lockwashers
and flat washers holding the motor to the
mounting bracket.
f. Loosen the setscrews in the motor pulley and
remove pulley by using a suitable puller.
NOTE: Refer to wiring diagram when rewiring the
motor.
g. After installing motor, adjust drive belt tension,
and adjust motor position on mounting bracket.