M411429 95
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
116. AIRFLOW SWITCH
Refer to Figure 42.
IMPORTANT: Airflow switch disc must remain
closed during operation. If it opens during the
drying cycle, insufficient airflow through the
tumbler is indicated. If switch remains open, or
pops open and closed during the cycle, the heating
system will shut off. The cylinder and fan will
continue to operate even though the airflow switch
is malfunctioning.
The airflow switch is set at the factory for proper
operation. However, at installation, and following
repairs, the airflow switch operation should be
checked. The airflow switch operation is
controlled by the counterweight position on the
shaft. Moving the counterweight changes airflow
switch sensitivity. The counterweight should be
adjusted so the airflow will force the disc away
from the cabinet when the lint panel is opened 1-
1/2 inches (38 mm). Adjust the airflow switch as
follows:
a. Load the tumbler with a 50 pound dry cotton
load.
NOTE: Airflow adjustment is much faster with one
person opening lint panel in front and another
adjusting the counterweight in the rear of tumbler.
b. Start the tumbler. Open the lint panel 1-1/2
inches (38 mm). The airflow disc should move
away from the cabinet, opening the switch
contacts and shutting off the heat system. This
indicates proper operation and proper
adjustment.
c. If switch is not opening as described in step b,
it should be adjusted so it is MORE sensitive.
Depress the spring clip and move
counterweight a small amount toward disc.
Retest by opening lint panel and continue
moving counterweight toward disc until switch
operates as described in step b.
d. If switch opens BEFORE lint panel is opened
the proper distance, in step b, it should be
adjusted so it is LESS sensitive. Depress the
spring clip and move counterweight a small
amount away from the disc. Retest by opening
lint panel and continue moving counterweight
away from disc until switch operates as
described in step b.
Airflow switch operation may be affected by
a clogged lint screen, lack of make-up air, or
by obstructions in the vertical recirculation
stack, or in the customer installed main or
collector ducts. These conditions MUST be
checked and necessary corrections made
before adjusting airflow switch. Always
check airflow at installation. Under no
circumstances is the airflow switch to be
blocked closed or bypassed.
W277
WARNING