To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
85. HEATER ELEMENT
(Electric Models)
Refer to Figure 16.
NOTE: Remove heater element from the rear of the
tumbler.
a. Remove two screws and lift hood assembly off
heater housing.
b. Remove nuts, disconnect wires and buss bars
from element terminals.
NOTE: Refer to wiring diagram when rewiring
element terminals.
c. Remove screws attaching element to rear of
heater housing.
d. Slide element toward front of tumbler and
carefully lift element up and out of heater
housing.
NOTE: Each tumbler is equipped with three
elements. Remove each element individually.
Figure 16
ELECTRIC HEATER
TU198-PT
HEATER
ELEMENTS
(3)
WIRES TO
CONTACTOR
BOX
NUT
BUSS
BAR
SCREW