ALLIANCE JT37CGI Service Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
M411429 15
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
6. PILOT DOES NOT IGNITE GAS MODELS (STANDING PILOT IGNITION)
7. PILOT GOES OUT GAS MODELS (STANDING PILOT IGNITION)
POSSIBLE CAUSE TO CORRECT
Gas shut-off valve to tumbler is closed. Open valve.
Air is present in gas line. Purge air from gas line.
Incorrect pilot orifice. Tumbler is equipped for type of gas specified on serial
plate. If pilot orifice is different from that specified on
serial plate, obtain and install correct orifice.
Clogged pilot gas filter. Replace reset assembly.
Clogged pilot gas tube or pilot orifice. Clean or replace tube or orifice.
Inoperative thermocouple. Replace thermocouple.
Inoperative pilot assembly. Replace pilot assembly.
POSSIBLE CAUSE TO CORRECT
Improper or inadequate exhaust system. Refer to Installation Manual (supplied with tumbler) for
exhaust system requirements.
Clogged lint screen. Remove and clean lint screen.
Improperly adjusted burner flame. Close air shutter slightly A harsh roaring flame will
draw pilot flame out.
Carbon accumulation on heated end of pilot
thermocouple.
Wipe carbon off end of thermocouple.
Incorrect pilot orifice. Tumbler is equipped for type of gas specified on serial
plate. If pilot orifice is different from that specified on
serial plate, obtain and install correct orifice.
Inoperative gas valve reset assembly or
thermocouple.
Check and replace reset assembly or thermocouple if
necessary.
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 100 101