  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
M411429 17
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
10. IGNITER GLOWS, SENSOR OPENS BUT NO IGNITION GAS MODELS
(Johnson Controls System)
NOTE: To check the primary and secondary valve coil and plunger operation, place fingers on top of coils,
cycle the machine and restart ignition circuit, you should feel the primary valve coil plunger open first,
followed by glow bar heat up, followed by the sensor opening, and the secondary valve coil plunger opening.
If plungers do not open, electrically check the coils. Check gas pressure to tumbler. Line pressure should be
7 ± 1/2 inches (Natural Gas) or 11 inches (L.P. Gas) water column pressure. Manifold pressure should be 3.5
inches (Natural Gas) or 11 inches (L.P. Gas) water column pressure.
11. IGNITER GLOWS, SENSOR OPENS BUT NO IGNITION GAS MODELS
(White Rodgers Glow-bar Ignition)
POSSIBLE CAUSE TO CORRECT
Insufficient gas supply. Check gas supply and pressure.
Gas flow but no ignition. Remove igniter and bracket and bend L shaped bracket
(located on left side of stove) up or down. Reinstall igniter
and bracket and check for 1/8 1/4 inch gap between
bottom of igniter and top of main burner.
No gas flow through gas valve. Check primary valve coil and plunger. Replace coil if
inoperative, or check for 120 Volts to control relay (PR1)
coil contacts (A) and 120 Volts to control relay (PR1)
contact number 7. If no voltage replace control relay
(PR1) or check secondary valve coil and plunger
operation replace coil if inoperative.
POSSIBLE CAUSE TO CORRECT
Insufficient gas supply. Is manual shut-off valve in full open position? Check gas
pressure.
Gas flow but no ignition. Gap between igniter and burner must be 1/8 to 1/4 inch.
No gas flow through gas valve. Check for 80 120 Volts between red and white wire on
gas valve.
If correct voltage is present and redundant coil does not
click open, replace complete gas valve.
If correct voltage is not present, replace diode logic board.
If correct voltage is present and redundant coil clicks
open, check for 40 60 Volts across the purple wires on
the main coil after the igniter cycles off.
If voltage is present and main coil does not stay open,
replace main coil.
If no voltage is present, replace diode logic board.