Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
14. HEATING ELEMENT OR BURNER REPEATEDLY CYCLES OFF ON HIGH LIMIT
THERMOSTAT
15. HEATING ELEMENT OR BURNER DOES NOT SHUT-OFF
16. CLOTHES DO NOT DRY
POSSIBLE CAUSE TO CORRECT
External exhaust system is longer than
recommended or inadequate make-up air.
Refer to Installation Manual (supplied with tumbler) for
exhaust and make-up air requirements.
Clogged lint screen. Remove screen and clean. Lint screen and compartment
should be cleaned after every eight hour shift.
Lint in tumbler ducts. Clean tumbler ducts.
Lint in external exhaust system. Disassemble exhaust system and clean.
High limit thermostat cycling at too low a
temperature.
Replace thermostat.
Lint door panel not closed properly. Open lint door panel place lint door panel back on
tumbler (ensuring a tight fit) then latch.
POSSIBLE CAUSE TO CORRECT
Gas Models:
Impurities on gas valve seat, preventing valve
from closing.
Replace gas valve.
Inoperative drying timer, relay or contactor. Replace timer, relay or contactor.
Incorrect wiring. Refer to wiring diagram located on back of tumbler or in
literature packet.
POSSIBLE CAUSE TO CORRECT
Heat source inoperative. Refer to Paragraph 5.
Too much water in articles being dried. Remove excess water.
Clothes load too large. Remove part of load.
Improper or inadequate exhaust system. Refer to Installation Manual (supplied with tumbler) for
exhaust requirements.
Heat source shuts-off prematurely. Refer to Paragraph 13.
Drying timer improperly set. Set selector for higher setting.
Incorrect voltage. Refer to Installation Manual (supplied with tumbler) for
electrical requirements.
Inadequate make-up air. Refer to Installation Manual (supplied with tumbler) for
make-up air requirements.