ALLIANCE JT37CGI Service Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
M411429 21
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
20. TUMBLER RUNS BUT NO STEAM TO COILS STEAM MODELS
21. WATER IN STEAM LINE STEAM MODELS
POSSIBLE CAUSE TO CORRECT
Valves closed. Check all valves in supply and return lines, make sure
they are open.
Blocked steam trap. Remove trap and clean. Replace if inoperative.
Inoperative solenoid valve. Check operation of solenoid valve.
Incorrect installation of check valve. Check for inlet and outlet markings on check valve, and
invert if necessary.
Clogged strainer. Remove strainer and clean.
Inoperative timer or thermostat Test timer or thermostat. Replace if inoperative.
POSSIBLE CAUSE TO CORRECT
Incorrect installation of steam piping. Refer to Installation Manual (supplied with tumbler) for
steam requirements.
Trap functioning improperly. Check trap for size and capacity. If trap is dirty or sluggish
clean thoroughly or replace. Check return line for high
back pressure.