ALLIANCE JT37CGI Service Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 101
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
M411429 25
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
25. SPARK TO PILOT BURNER NO PILOT FLAME
(Electronic Pilot Ignition Models Only)
24 VOLTS BETWEEN
TERMINAL 1 AND
GROUND ON
ELECTRONIC
PACKAGE
YES
NO
GAS PRESENT AT
PILOT BURNER
(Disconnect white wire
from Terminal 3 and
light manually)
YES
REPLACE
ELECTRONIC
PACKAGE
REMOVE BLACK WIRE
FROM TERMINAL 1.
MOMENTARILY TOUCH TO
TERMINAL 2; IS CLICK
HEARD?
NO
REFER TO
NO SPARK TO
PILOT BURNER
CLEAR
OBSTRUCTION
PILOT FILTER,
TUBE OR
ORIFICE
OBSTRUCTED
YES
NO
YES
REPLACE RIGHT COIL
(PILOT OPERATOR)
NO
YES
YES
YES
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 100 101