M411429 49
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
53. CD MODELS: NO START WITH VEND SATISFIED AND START BUTTON PUSHED
120 Volt/60 Hertz/1 Phase Gas Nonreversing
NOTE: All voltage checks are referenced to neutral unless stated otherwise.
NOTE: If the motor only runs with the start switch pressed in, that means the centrifugal switch in the motor
is bad. Replace the motor.
Step Problem If No, then
1 Is there voltage to the NC terminal of switch A?
If yes, continue to next step.
Correct wiring between L1 on TBI and switch A.
2 Is there voltage to COM terminal of switch A?
If yes, continue to next step.
Check for proper operation of switch A. Replace switch
A if necessary.
3 Is there voltage to COM terminal of the door switch?
If yes, continue to next step.
Correct wiring between door switch and switch A of the
rotary coin drop.
4 With the door closed, is there voltage to the N.O. terminal
of the door switch? If yes, continue to next step.
Check door switch for proper operation, replace if
necessary.
5 Is there voltage to terminal 5 of the motor? If yes, continue
to next step.
Correct wiring between motor and door switch.
6 Is there voltage to the input side of the start switch?
If yes, continue to next step.
Correct wiring between start switch and door switch.
7 With the start button pressed in, is there voltage to the
output side of the start button? If yes, continue to next step.
Replace start switch.
8 Is there voltage to terminal 1 of the motor? If yes, continue
to next step.
Correct wiring between motor and start switch.
9 Does the motor run? If yes, continue to next step. Replace the motor.
10 Unit operational.